Technical Specification: 9mm
Impact Resistance | 5KJ/m2 | Bending Strength | 14 Mpa |
Sound Insulation | 42DB | Thermal Condctivity | 0.153W/mk |
Pull out strength | 34N | Thickness Tolerance | ±0.2mm |
R-Value | 0.082m2K/W | Weigtht per Sheet | 31kg |
Effects to Acid and Alkali | No Effect | Shrinkage/Swelling Rate | ≤0.25% |
Freeze-Thaw 100 Cycles | ≥ 0.99 | Chloride ion Content | <0.1% |
Color | White/Gray | Thensile strength | 1.6Nmm2 |
*Further sizes available on request
** Board Dimensions: 2440 x 1220 mm
Installation
A-2 sheets of panel are connected naturally.
B-A gap of 5mm must be reserved between the two panels to embed seam fillers. Also 3-5mm gaps for the top and bottom.
C- When the height of wall is over 3m, the vertical joints should installed staggered, 5mm away from the ceiling and floor.
D-Use our self-drilling screws to connect the board from its center to the adjacent fixed board. The distance protection is 15mm from the edge of the board, 50mm from the board, and 300mm from the fixed point. All screws should sink into the panel by 1-2mm.
The environmental requirements of joint filler should comply with the instructions. It is recommended to use self-adhesive mesh tape and drywall tape.
Material And Chemical Safety Data Sheet
These boards are classified as non-hazardous substances. Dust may cause irritation to the nose, throat, and respiratory tract, causing coughing and sneezing. Skin contact may cause irritation, but it will not be absorbed by the skin.
When handling the boards that may generate dust, follow practices to restrain the release. Work outdoors wherever possible and wear dust masks to reduce exposure. Wear safety goggles/glasses and gloves when cutting. Direct contact with the skin should be avoided.
The boards are not classified as a hazardous substance and contain NO FORMALDEHYDE or
ASBESTOS. No special provision is required regarding carriage and disposal of the boards.
IF ANY ADVERSE SYMPTOMS PERSIST, SEEK MEDICAL ADVICE.